Glycol water tank with 100mm thickness polyethylene insulation, Increase the low temperature holding time of ice water and save the working time of brazing chiller. PU level meter help brewmaster to check the water volume and decide glycol adding volume.
Normally the design of glycol water tank manhole on the top, not easy to do this. Tank breath port design use SUS elbow, preventing negative pressure in tank, reduce natural evaporation of ethylene glycol. 4 pieces one layer Industrial 304 Stainless Steel Legs with adjusting bolt.
Beer Glycol System – Chiller
1 | Model | RHP-7 |
2 | Voltage | 3 phase 380V 50Hz |
3 | Total power | 13.8 KW |
4 | Rated refrigeration capacity | 8.22 KW |
5 | Compressor | Brand: Copeland,
Type: totally enclosed, Starting mode: Sequential direct start, |
6 | Condenser | KAIDI, China,
Corrugated aluminum fins with high efficiency copper tube sheath, Codenserfanflowrete: 3.07m3/h |
7 | Cryogen | Juhua R404A |
8 | Built in pump | Zhejiang Leo multistage pump,
Power: 0.55kw, lift: 20m, water inlet: 32mm |
9 | Evaporator | Jiangsu Yuan Zhuo, China |
10 | Sanhua Expansion Valve | Tianjin, China |
11 | Voltage Controller | HONGSEN, China |
12 | Pressure meter | HONGSEN, China |
13 | Temperature Control Range, Temperature and Control Accuracy | 0–10 |
14 | Safety protection device | High and low voltage switch, anti-freezing protection, overload protection device, coil overheat protector, temperature automatic protection switch, etc. |
15 | Frozen water nozzle size | 32mm |
16 | Dimension (mm) | 1400mm * 800mm *1400mm |
17 | Wight (kg) | 310kgs |
18 | Remark | The working condition of above refrigeration capacity is 5℃ of water inlet temperature. The effluent temperature is – 5℃. The ambient temperature is 35℃. |